Leica TS60 Robotic Total Station

Brand Name : Leica

Model Number : TS 60

Country of Origin : Switzerland

ANGLE MEASUREMENT
Accuracy 1 Hz and V Absolute, continuous, diametrical 0.5” (0.15 mgon) or 1” (0.3 mgon)
DISTANCE MEASUREMENT
Range 2 Prism (GPR1, GPH1P) 3
Non-Prism / Any surface 4
0.9 m to 3,500 m
0.9 m to >1,000 m
Accuracy / Measurement time Single (prism) 2,5
Single (any surface) 2,4,5,6
1 mm + 1 ppm / typically 2.4 s
2 mm + 1 ppm / typically 1.5 s 10
2 mm + 2 ppm / typically 2 s 9
Laser dot size At 50 m 8 mm x 20 mm
Measurement technology System analyser Coaxial, visible red laser
IMAGING7
Overview and telescope camera Sensor
Field of view (overview / telescope)
Frame rate
5 megapixel CMOS sensor
19.4° / 1.5°
Up to 20 frames per second
MOTORISATION
Direct drives based on Piezo technology Rotation speed / Time to change face Maximum 200 gon (180°) per s / typically 2.9 s
AUTOMATIC AIMING – LONG RANGE ATRplus
Target aiming  range2 Circular prism (GPR1, GPH1P)
360° prism (GRZ4, GRZ122)
3,000 m
1,500 m
Accuracy 1,2 / Measurement time ATRplus angle accuracy Hz, V 0.5” (0.15 mgon) or 1” (0.3 mgon) / typically 3-4 s
GENERAL
Operating System / Field Software Windows EC7 / Leica Captivate with apps  
Processor TI OMAP4430 1GHz Dual-core ARM® Cortex™- A9 MPCore™ 1.0 mm (1 Sigma)
Autofocus telescope Magnification / Focus Rang 0.7 m to 2.7 m
AutoHeight Module Distance accuracy
n Distance range
Operating time up to 8 h
Display and keyboard 5“ (inch), WVGA, colour, touch, both faces Running on field controller
Operation 3x endless drives, 1x Servofocus drive, 2x Autofocus keys 8, user-definable SmartKey On field controller
Power management Exchangeable Lithium-Ion battery with
internal charging capability
 
Data storage Internal memory
Memory card
2 GB
SD card 1 GB or 8 GB
Interfaces RS232, USB, Bluetooth®, WLAN 20°C to +50°C
IP55 / 95%, non-condensing
Weight Total station including battery 7.2 kg
Environmental specifications

Working temperature range
Dust & Water (IEC 60529) / Blowing rain
Humidity

-20°C to +50°C
IP65 / MIL-STD-810G, Method 506.5-I
95%, non-condensing