ANGULAR MEASUREMENT |
||
Accuracy Hz and V | Absolute, continuous, diametrical1 | 2’’ / 3’’ / 5’’ |
● Display resolution: 0.1’’ (0.1 mgon) ● Quadruple axis compensation ● Compensator range: +/- 4’ ● Electronic level resolution: 2“ ● Circular level sensitivity: 6` / 2 mm |
✔ | |
DISTANCE MEASUREMENT | ||
Range | ● Prism (GPR1, GPH1P): 0.9 m to 3,500 m ● Prism GPR1 (Long Range mode) > 10,000 m |
✔ |
Non-Prism / Any surface ● R5003 ● R10004 |
✔ ✗ |
|
Accuracy / Measurement time | Single prism ● Precise+ / Once: 1 mm + 1.5 ppm (typical 2.4 s) ● Precise&Fast / Once&Fast: 2 mm + 1.5 ppm (typical 2 s) ● Tracking / Continously: 3 mm + 1.5 ppm (typical < 0.15 s) ● Averaging: 1 mm + 1.5 ppm ● Long Range mode / > 4 km: 5 mm + 2 ppm (typical 2.5 s) |
✔ |
Non-Prism / Any surface ● 0 m – 500 m: 2 mm + 2 ppm (typical 2.4 s5) ● > 500 m: 4 mm + 2 ppm |
✔ | |
Laser dot size | ● At 30 m: 7 mm x 10 mm ● At 50 m: 8 mm x 20 mm ● At 100 m: 16 mm x 25 mm |
✔ |
Telescope | ● Magnification: 30x ● Resolving power: 3” ● Focusing range: 1.55 m / 5.08 ft to infinity ● Field of view: 1°30’ / 1.66 gon / 2.7 m at 100 m |
|
GENERAL |
||
Display and keyboard | 3.5“ (inch), 320 x 240 px QVGA, grayscale, 28 keys6a |
|
Operation | Endless drives for HZ & V ● Trigger-Key: user definable with 2 functions |
✔ |
Power management | Exchangeable Lithium-Ion battery7 ● Operating time with GEB364 ● Operating time with GEB334 Battery charging time with ● GKL341 charger for GEB364 / GEB334 ● GKL311 charger for GEB364 / GEB334 |
up to 32 h up to 16 h 3 h 30 min / 3 h |
External supply voltage ● Nominal voltage 13.0 V DC & 16 W max |
✔ | |
Data storage | ● Internal memory: 4 GB Flash ● Memory card: SD card 1 GB or 8 GB ● USB memory stick: 1 GB |
✔ |
Processor | ● TI OMAP4430 1GHz Dual-core ARM® Cortex™ A9 MPCore™ ● Operating system – Windows EC7 |
✔ |
Interfaces | RS2328, USB device Betooth®9, WLAN10 |
✔ ✗ ✗ |
Guide Light (EGL) | Working range: 5 m to 150 m ● Position accuracy: 5 cm at 100 m ● Wavelength red /orange: 617 nm / 593 nm |
✗ |
Laser plummet (Laserclass 2) |
Accuracy ● Plumb line deviation: 1.5 mm at 1.5 m instrument height ● Diameter of laser point: 2.5 mm at 1.5 m instrument height |
✔ |
AutoHeight module for automatic instrument height measurement (Laserclass 2) |
Accuracy ● Distance accuracy: 1.0 mm (1 Sigma) ● Distance range: 0.7 m to 2.7 m |
✗ |
Weight | 4.3 kg | |
Environmental specifications | ● Working temperature range: –20°C to +50°C11 ● Arctic version: –35°C to +50°C ● Dust / Water (IEC 60529) / Humidity: IP66 / 95%, non-condensing ● Military Standard 810G, Method 506.5 |
✔ ✗ ✔ ✔ |
LOC8 | Tracking and theft deterrence device |