Leica Total Station (TS03)

Brand Name : Leica

Model Number : TS03

Country of Origin : Switzerland

ANGULAR MEASUREMENT
Accuracy Hz and V Absolute, continuous, diametrical1 2’’ / 3’’ / 5’’
  ● Display resolution: 0.1’’ (0.1 mgon)
● Quadruple axis compensation
● Compensator range: +/- 4’
● Electronic level resolution: 2“
● Circular level sensitivity: 6` / 2 mm
DISTANCE MEASUREMENT
Range ● Prism (GPR1, GPH1P): 0.9 m to 3,500 m
● Prism GPR1 (Long Range mode) > 10,000 m
  Non-Prism / Any surface
● R5003
● R10004

Accuracy / Measurement time Single prism
● Precise+ / Once: 1 mm + 1.5 ppm (typical 2.4 s)
● Precise&Fast / Once&Fast: 2 mm + 1.5 ppm (typical 2 s)
● Tracking / Continously: 3 mm + 1.5 ppm (typical < 0.15 s)
● Averaging: 1 mm + 1.5 ppm
● Long Range mode / > 4 km: 5 mm + 2 ppm (typical 2.5 s)
  Non-Prism / Any surface
● 0 m – 500 m: 2 mm + 2 ppm (typical 2.4 s5)
● > 500 m: 4 mm + 2 ppm
Laser dot size ● At 30 m: 7 mm x 10 mm
● At 50 m: 8 mm x 20 mm
● At 100 m: 16 mm x 25 mm
Telescope ● Magnification: 30x
● Resolving power: 3”
● Focusing range: 1.55 m / 5.08 ft to infinity
● Field of view: 1°30’ / 1.66 gon / 2.7 m at 100 m
 
GENERAL
Display and keyboard 3.5“ (inch), 320 x 240 px QVGA, grayscale,
28 keys6a
 
Operation Endless drives for HZ & V
● Trigger-Key: user definable with 2 functions
Power management Exchangeable Lithium-Ion battery7
● Operating time with GEB364
● Operating time with GEB334
Battery charging time with
● GKL341 charger for GEB364 / GEB334
● GKL311 charger for GEB364 / GEB334
up to 32 h
up to 16 h

3 h 30 min / 3 h
6 h 30 min / 3 h 30 min

  External supply voltage
● Nominal voltage 13.0 V DC & 16 W max
Data storage ● Internal memory: 4 GB Flash
● Memory card: SD card 1 GB or 8 GB
● USB memory stick: 1 GB
Processor ● TI OMAP4430 1GHz Dual-core ARM® Cortex™ A9 MPCore™
● Operating system – Windows EC7
Interfaces RS2328, USB device
Betooth®9, WLAN10


Guide Light (EGL) Working range: 5 m to 150 m
● Position accuracy: 5 cm at 100 m
● Wavelength red /orange: 617 nm / 593 nm
Laser plummet
(Laserclass 2)
Accuracy
● Plumb line deviation: 1.5 mm at 1.5 m instrument height
● Diameter of laser point: 2.5 mm at 1.5 m instrument height
AutoHeight module for automatic
instrument height measurement
(Laserclass 2)
Accuracy
● Distance accuracy: 1.0 mm (1 Sigma)
● Distance range: 0.7 m to 2.7 m
Weight 4.3 kg  
Environmental specifications ● Working temperature range: –20°C to +50°C11
● Arctic version: –35°C to +50°C
● Dust / Water (IEC 60529) / Humidity: IP66 / 95%, non-condensing
● Military Standard 810G, Method 506.5



LOC8 Tracking and theft deterrence device