ANGLE MEASUREMENT | ||
Accuracy 1 Hz and V | Absolute, continuous, diametrical | “1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon), 5’’ (1.5 mgon)” |
DISTANCE MEASUREMENT | ||
Range 2 | Prism (GPR1, GPH1P) 3 n Non-Prism / Any surface 4 |
0.9 m to 3,500 m R500: 0.9 m to >500 m R1000: 0.9 m to >1,000 m |
Accuracy / Measurement time | Single (prism) 2,5 Single (prism fast) 2,5 Single (any surface) 2,4,5,6 |
1 mm + 1 ppm / typically 2.4 s 2 mm + 1 ppm / typically 1.5 s 10 2 mm + 2 ppm / typically 2 s 9 |
Laser dot size | At 50 m | 8 mm x 20 mm |
technology | System analyser | Coaxial, visible red laser |
Measurement technology | System analyser | Coaxial, visible red laser |
AUTOMATIC AIMING – ATRplus |
||
Target aiming range2 / Target locking range2 | Circular prism (GPR1, GPH1P) 360° prism (GRZ4, GRZ122) |
1,000 m 800 m |
Accuracy 1,2 / Measurement time | ATRplus angle accuracy Hz, V | 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon), 5’’ (1.5 mgon) / typically 3-4 s |
GUIDE LIGHT (EGL) |
||
Working range / Accuracy | 5 – 150 m / typically 5 cm @ 100 m | |
GENERAL |
||
Processor | TI OMAP4430 1 GHz Dual-core ARM® Cortex™- A9 MPCore™ | |
AutoHeight module for automatic | Distance accuracy | 1.0 mm (1 Sigma) |
instrument height measurement | Distance range | 0.7 m to 2.7 m |
Power management | Exchangeable Lithium-Ion battery | Operating time up to 8 h |
Field software | Leica Captivate with apps | Running on field controller |
Data storage | Internal memory 2 GB SD card 1 GB or 8 GB |
On field controller |
Interfaces | RS232, USB, Bluetooth®, WLAN | |
Weight | Total station including battery | 5.0 kg |
Environmental specifications |
Working temperature range |
20°C to +50°C IP55 / 95%, non-condensing |