System Specification
ANGLE MEASUREMENTA2:G27B1A2:G23A2:A2:G30 | ||
---|---|---|
Accuracy 1 Hz and V | Absolute, continuous, diametrical | 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon), 5’’ (1.5 mgon) |
DISTANCE MEASUREMENT | ||
Range 2 | Prism (GPR1, GPH1P) 3 Non-Prism / Any surface 4,9 |
0.9 m to 3,500 m R500: 0.9 m to >500 m R1000: 0.9 m to >1,000 m |
Accuracy / Measurement time | Single (prism) 2,5 Single (prism fast) 2,5 Single (any surface) 2,4,5,6 |
1 mm + 1 ppm / typically 2.4 s 2 mm + 1 ppm / typically 1.5 s 11 2 mm + 2 ppm / typically 2 s 7 |
Laser dot size | At 50 m | 8 mm x 20 mm |
Measurement technology | System analyser | Coaxial, visible red laser |
IMAGING | ||
Overview camera | Sensor | 5 megapixel CMOS sensor |
Field of view | 19.4° | |
Frame rate | Up to 20 frames per second | |
AUTOMATIC AIMING – ATRplus | ||
Target aiming range2 / Target locking range2 | Circular prism (GPR1, GPH1P) | n 1,500 m / 1,000 m |
360° prism (GRZ4, GRZ122) | n 1,000 m / 1,000 m | |
Accuracy 1,2 / Measurement time | ATRplus angle accuracy Hz, V | 1” (0.3 mgon), 2” (0.6 mgon), 3” (1 mgon), |
5” (1.5 mgon) / typically 3-4 s | ||
LASER GUIDE | ||
Spot Size8 / Range | Daylight: 30 mm @250 m | 250 m |
Darkness: 65 mm @300 m | 500 m | |
POWERSEARCH | ||
Range / Search time | 360° prism (GRZ4, GRZ122) | 300 m / typically 5 s |
GUIDE LIGHT (EGL) | ||
Working range / Accuracy | 5 – 150 m / typically 5 cm @ 100 m | |
GENERAL | ||
Operating System / Field Software | Windows EC7 / Leica Captivate with apps | |
Processor | TI OMAP4430 1GHz Dual-core ARM® Cortex™- A9 MPCore™ | |
AutoHeight module for automatic | Distance accuracy | 1.0 mm (1 Sigma) |
instrument height measurement | Distance range | 0.7 m to 2.7 m |
Display and keyboard | 5″ (inch), WVGA, colour, touch, face I standard / | 37 keys, illumination |
face II optional | ||
Power management | Exchangeable Lithium-Ion battery | Operating time up to 8 h |
Data storage | Internal memory / Memory card | 2 GB / SD card 1 GB or 8 GB |
Interfaces | RS232, USB, Bluetooth®, WLAN | |
Weight | Total station including battery | 5.1 – 5.8 kg |
Environmental specifications | Working temperature range | -20°C to +50°C |
Dust & Water (IEC 60529) / Humidity | IP55 / 95%, non-condensing |